We recommend 200-300Ah, although please note that this is subjective as others have used them on 800-1000Ah.
Typically we adopt the logic that if a battery is totally out of balance (all full with one empty or vice versa) the system should be able to automatically equalise within ~1 week. Hence, if a LongMon can sustain 5W or ~1.2A bypass and there are 168 hours in a week, this results in approx 200Ah.
The reality is if you go larger, it will take longer.
Remember that this is the worst case and most of the time it's negligible balancing on a daily basis when the pack have been balanced. This requirement is only needed when recovering from a problem or on initial commission if people do not pre-balance. Our customers typically don't pre-balance, hence why we suggested sizing.
1000Ah will take 5 weeks, for this is acceptable but we think it is not ideal.
If you have a large capacity on many cells, consider multiple strings, which have their own pros and cons.
Up to 250 cell monitors.
With the aggregator functionality now we can have one master supervisor listen to up to 70 satellite supervisors, each having 250 cells.