Discontinued cell monitor
- Battery range 2.2V to 5.4V.
- Bypass current 0A to 2A (typically 1A).
- Over-temperature protection.
- Over-voltage protection up to ±20V.
- Noise immune opto-isolated.
- Cell temperature and bypass load temperature measurements.
- USB monitoring of live individual cell parameters and remote cell diagnostics.
- Sealed in black thermally conductive epoxy (robust and safe).
- Red and green LEDs for diagnostics and status.
- All parameters fully remotely programmable and software is remote upgradeable.
TopMon shares the same specs as the LongMon.