The administrative screen provides telemetry for the WatchMon supervisor hardware, and how to understand the various fields shown.
This screen is accessed via the Telemetry option on the Menu, then choosing the Daily History tab and then Extract.
Used to retrieve the individual session summary (3650 days ~ 10 years). Method to extract all the records into a file that can be reviewed in a spreadsheet. Bulk extract to file is available when connected via USB.
After processing will show a subset of the collected values.
My Documents \ Batrium \ Logs \ #Date# \ History_#SysCode#.txt
#Date# is today's date
#SysCode# is the system code
LogID | # |
LogDate | yyyy-MM-dd |
LogTime | HH:mm:ss |
CriticalEvents | # |
MinCellVolt | Volt |
MaxCellVolt | Volt |
MinThermal | ºC |
MaxThermal | ºC |
MinSoc | % Percent |
MaxSoc | % Percent |
MinShuntVolt | Volt |
MaxShuntVolt | Volt |
MinSupplyVolt | Volt |
MaxSupplyVolt | Volt |
PeakAmpCharge | Amp |
PeakAmpDischg | Amp |
CumulAhCharge | Ah |
CumulAhDischg | Ah |
SocBand-A | hour |
SocBand-B | hour |
SocBand-C | hour |
SocBand-D | hour |
SocBand-E | hour |
SocBand-F | hour |
SocBand-G | hour |
SocBand-H | hour |
ThermalBand-A | hour |
ThermalBand-B | hour |
ThermalBand-C | hour |
ThermalBand-D | hour |
ThermalBand-E | hour |
ThermalBand-F | hour |
ThermalBand-G | hour |
ThermalBand-H | hour |
Pressing this button calls up the knowledge base on this screen.