For new installations download setup at WatchMonToolkitInstaller_2.17.55
You may need to copy and paste the following URL into your browser and press keep to get it to start
https://link.batrium.com/s55nxs
File created: 25 July 2024
- Dynamic voltage targets for controlling remote inverters
- enhanced approach on sending status updates to BMI for web access
- improvements to the firmware to enable BMI charting within the webapp (soon to be rolled out)
- add Pincode acknowledgement when changing pin.
- adopt new defaults for Setup Wizard to match the typical WMC + CellMateK9 system
- additional fixes to handle WIFI network stability on some devices with dropouts and unable to reconnect or fetch IP
For new installations download setup at WatchMonToolkitInstaller_2.17.54
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/s54mre
File created: 4 March 2024
- Firmware improvements for iPhone and Android mobile applications now available
- Improved web provisioning for devices to web access
- Resolved WIFI network stability on some devices with dropouts and unable to reconnect or fetch IP
For new installations download setup at WatchMonToolkitInstaller_2.17.51
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/s51cwe
Status: Latest release
File created: 6 Jan 2024
- Allow remote web access with BMI and registration
- Enable factory erase with a authorisation phrase so can be done without a zoom tech support session
- Improved web provisioning for devices to web access
Download setup at WatchMon Toolkit Installer 2.17.46
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/s46dca
File created: 29 August 2023
Upgrades to this preview release are not recommended for older hardware (WM4/WM5/MM8). We will announce as soon as it is ready for adoption.
Please define your timezone and update the time sync feature when updating to this release.
You might need to restart the device and set the timezone a couple of times to get it accurate, as outlined in this section: Extra Help to Check if Device Time is Working Properly
- WatchMonCORE supervisor is now able to communicate with CellMate-K9
- IngeTeam SunStorage CANbus profile
- Control > Remote logic now has ramp-down functionality for some inverters with CAN bus at full and empty
- CANbus profile to emulate the Pylon Tech HighVolt battery
- CANbus profile BydESS swap MaxAmpLimit for Charge/Discharge
- Adjust OpStatusLed to yellow (restart) when processing the MQTT firmware update
- Prevent firmware updates when using WiFi
- Add daily session cell volt min/max to node chart
- For web firmware updates, ensure a restart connection on completion
- WiFi discovery deals with unhandled error
- Allow supervisor to run in satellite mode allowing more than 250 cells with each CMU string aggregated to Min/Max/Avg to master
- Automatic bootloader upgrade for WatchMon firmware updates
- Improvements to beta web access to improve device provisioning
- Improve the WiFi Join Network function that had difficulty on some routers
- Watchdog restart of the device if required
- Shunt Re-Calibration when in Bypass freeze/reset (should only be when not 100% and Bypass Complete flag set)
- Bypass Tester function to handle slow/large CMU networks and display the reason why the fault occurred
- On full factory reset to fix the initial defaulting of some values and ensure that WebAccess(MQTT) is disabled
- Web access detects correct FW HW versioning (a feature that used to be read-only)
- Fixed the Cellmate-K9 poller when collecting set up to improve the process to recalculate the First/Last if less than all the modules
For new installations download setup at WatchMonToolkitInstaller_2.17.39
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/k39heb
Status: LATEST release
File created: 19 April 2023
Download Link: WatchMonToolkitInstaller_2.17.27.msi
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/ace27c
File created: 28 September 2022
Download Link: WatchMonToolkitInstaller_2.17.15.msi
You may need to copy and paste the following URL into your browser for it to start
https://link.batrium.com/7c87aa
File created: 20 December 2021
Prior build was WatchMonToolkitInstaller_2.17.9.msi from 23 August 2021
You may need to copy and paste the following URL into your browser for it to start: https://link.batrium.com/a6112e