It may be necessary to run a BridgeConnect with the twin canbus ports running in pass-through mode to provide ground isolation from the charger traction battery supply and WatchMon ground reference.
CAUTION: Example below has values shown for a demo LiFePO4 cell pack. Ensure you adopt values suitable to your application.
Note: 120 Ohm resistor shares CANbus High and CANbus Low
NB: Add 120ohm terminating resistor on charging lead.
Open the WatchMon Toolkit and navigate to the Integration Settings by clicking the Menu then Hardware and select Integration Tab.
Select Canbus protocol to "EnPowerCharger" and Save.
On WatchMon Toolkit, navigate to Control Logic menu, then Charging tab.
Adjust the Charging Control Logic to suit the application.
Notes:
Navigate to Hardware, then CellMon tab.
Adjust the CellMon Bypass Voltage to suit the application.
Note: Make sure to "Device Sync" the changes to the CellMons.
Navigate to the Remote tab on the Control Logic screen.
Notes:
Navigate to Telemetry, then Live Stats to observe system operation.