Guide article of the new Toolkit3 app to allow users to configure the Expansion Hardware Settings.
Navigate to the screen via the Menu and choose the Configuration tab. Choose Expansion Hardware from the drop-down menu.
Editing is only available when in 'Technician' mode.
For guide on how to make changes, go to Configuration Guide and Icons.
Select from the template list the appropriate supervisor and expansion board on your setup.
The Output and Input fields can be set individually. There are Relays on the Expansion board and 6 MOSFET outputs on the Expansion Board plus 2 outputs on the WatchMon.
Setting | Definition | Notes and Where to Find Current State |
---|---|---|
None | No Function selected | |
Manual On | Force relay switch to ON |
|
CriticalBattOK | On when in Critical Battery OK mode. Batt happy -ON Critical - OFF |
|
Charging On | ON when charging is on | |
Discharging On | ON when discharging is on | |
Heating Required | ON when Heating required | |
Cooling Required | ON when Cooling required | |
Run/Idle input | Used for EV; mostly a combination of Discharging and Critical to protect from over-discharging |
|
Charge/Normal input | Used for EV; mostly a combination of Charging and Critical to protect from overcharging | |
Bypass Complete | ON when all cell monitors have gone into bypass complete | |
Charging Limited | ON when Charging Limited | |
Discharging Limited | ON when Discharging Limited | |
Critical Recovery | Setup to suit the requirements of a specific customer Do Not Use |
|
Critical Pulse On | 200ms pulse sent Reverse logic of Critical Pulse OFF | |
Critical Pulse Off | 200ms pulse sent when Critical State turns to OFF used to trigger Circuit Breakers | |
Critical Fault | Reverse logic of Critical Battery OK Batt happy - OFF Critical - ON |
|
Critical Precharge Timer | Circuit is 2 seconds - pulse relay for 2 seconds to pre-charge and it does not spark |
|
Fluid pump required | ON when either Heating or Cooling is required | |
Strip cycle discharge | Setup to suit the requirements of specific customer Do Not Use |
|
Strip cycle isolate | Setup to suit the requirements of specific customer Do Not Use |
|
Warning HVA charge | CV2 breached | |
Warning LVA discharge | CV11 breached | |
Charging Remote Running | ON based on control logic in the remote tab. | |
Charging Off | Reverse logic of Charging ON | |
Discharging Off | Reverse logic of Discharging ON | |
Bypass Fan Prolonged | ON if any of the cell monitors in bypass and will switch off one minute when all have stopped | |
Charging Alternative | Setup based on Alternative values | |
Discharging Alternative | Setup based on Alternative values | |
Charging Strip | Setup to suit the requirements of specific customer Do Not Use |
|
SOC% Limit 1 | Setup based on SOC% Limits | |
SOC% Limit 2 | Setup based on SOC% Limits | |
SOC% Limit 3 | Setup based on SOC% Limits | |
SOC% Limit 4 | Setup based on SOC% Limits | |
Reserved34 | Setup to suit the requirements of specific customer Do Not Use |
|
Reserved35 | Setup to suit the requirements of specific customer Do Not Use |
|
Reserved36 | Setup to suit the requirements of specific customer Do Not Use |
|
Reserved | Setup to suit the requirements of specific customer Do Not Use |