CAUTION: Only undertake if you have access to Brusa technical support as this product is not trivial to get operational.
Photo of Fan-Cooled Brusa NLG5 charger
Photo of Liquid-Cooled Brusa NLG5 charger
Adopting the Brusa NLG5 charger can be configured as follows within the WatchMon supervisor. It may be necessary to run a BridgeConnect with the twin CANbus ports running in pass-through mode to provide ground isolation from the traction battery supply and WatchMon ground reference.
CAUTION: Example below has values shown for a demo LiFePO4 cell pack. Ensure you adopt values suitable to your application.
Adopting the Brusa NLG6 charger can be configured as follows within the WatchMon supervisor. It may be necessary to run a BridgeConnect with the twin canbus ports running in pass-through mode to provide ground isolation from the traction battery supply and WatchMon ground reference.
CAUTION: Example below has values shown for a demo LiFePO4 cell pack. Ensure you adopt values suitable to your application.
Note: 120 Ohm resistor shares CANbus High and CANbus Low
NB: Add 120ohm terminating resistor to charging plug.
Open Watchmon toolkit and navigate to Integration Settings by clicking the Menu then Hardware and select Integration Tab.
Select Canbus protocol for Brusa "Brusa NLG5 or Brusa NLG6" and Save.
On WatchMon Toolkit, navigate to Control Logic menu, then Charging tab.
Adjust the charging control logic to suit the application.
Notes:
Navigate to Hardware, then CellMon tab.
Adjust the CellMon bypass voltage to suit the application.
Note: Make sure to "Device Sync" the changes to the CellMons.
Navigate to the Remote tab on the Control Logic screen.
In this example below, the voltage was set to 310.8 volts, current to 4 amps and limited to 0.5 amps during balancing.
Notes:
Navigate to Telemetry, then Live Stats to observe system operation.