Administrative screen for the WatchMon supervisor hardware providing a summary, and how to understand and see the various fields available to configure the Temperature aspect of control logic.
This screen is accessed via the Control Logic option on the Menu, then choosing the TempView tab. Editing only available when in Technician mode.
Values read from device.
Cell temperature threshold that is OK to operate, if above will change state when monitoring is enabled, output is connected to the Critical Contactor.
Cell temperature warning when above will flash RED led on CellMon.
Cell temperature threshold that is OK to operate, if above will stop the discharging state when monitoring is enabled.
Cell temperature threshold that is OK to operate, if above will stop the charging when monitoring is enabled.
Cell temperature threshold that is OK to operate, if above will start the cooling control when monitoring is enabled.
Cell temperature threshold that is OK to operate, if below will start the heating control when monitoring is enabled.
Cell temperature threshold that is OK to operate charging, if below will stop the charging when monitoring is enabled.
Cell temperature threshold that is OK to operate, if below will stop the discharging state when monitoring is enabled.
Cell temperature threshold that is OK to operate, if below will change state when monitoring is enabled, output is connected to the Critical Contactor.
WatchMon supervisor temperature threshold that is OK to operate, if above will change state when monitoring is enabled, output is connected to the Critical Contactor.
WatchMon supervisor temperature threshold that is OK to operate, if above will stop the discharging state when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if above will stop the charging when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if above will start the cooling control when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if below will start the heating control when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if below will stop the charging when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if below will stop the discharging state when monitoring is enabled.
WatchMon supervisor temperature threshold that is OK to operate, if below will change state when monitoring is enabled, output is connected to the Critical Contactor.
Pressing this button calls up the knowledge base on this screen.
If figures shown on this page need changing, please go to the following links to change the designated items:
Hardware CellMon: CT8
Control Logic - Critical Battery OK: CT1, CT9, BT1, BT9
Control Logic - Charging Settings: CT3, CT6, BT3, BT6
Control Logic - Discharging Settings: CT2, CT7, BT2, BT7
Control Logic - Thermal Settings: CT4, CT5, BT4, BT5